| Overview
| Services
| Markets We Serve
| Locations
| Articles
| Career Oppt./Contact Us
| Misc.
VOC ELIMINATION
View our brochure
Navigation:
VOC Overview
VOCs Handling and Processing
Services We Provide
Area of UTI’s VOC Experience and Expertise
List of Recent Projects
Volitile Organic Compounds (VOCs)
Serving Industrial Clients In Processes, Facilities and Reduction of Emissions of Volatile Organic Compounds
VOC Elimination and Reduction is a primary concern to many companies that handle these compounds in their manufacturing processes. UTI has unique expertise and years of experience in the technologies used to reduce and/or eliminate VOC emissions.
The real key to success in the elimination of VOCs is understanding the process and determining the waste stream VOC loadings. Incorrect evaluations can lead to incorrect equipment selection, adverse impact on the cost of energy for eliminating VOCs and finally the impact on the manufacturing business.
VOCs Handling and Processing
Solvent Handling, including VOC Emission Reductions and Recovery
Odor Control through various technologies, such as Scrubbers, Carbon Adsorption, Bio Technology and Thermal Oxidation
Thermal Oxidation Systems ranging in size from 2,000 cfm to 250,000 cfm
Solvent Recovery Systems ranging in size from 5,000 cfm to 25,000 cfm
Bio Technologies up to 30,000 cfm
Incident Investigation of Failed Systems
Services We Provide
Full service engineering for industrial facilities and processes
Preliminary engineering and development of appropriation-grade engineering estimates
Development of process flow drawings and process instrumentation drawings
Project management
Construction management
Process optimization
Process modeling with ChemCAD
Process modeling empirically
Process hazard analysis (PHA)
Process safety management (PSM)
Process safety management audits
Pre-startup safety reviews (PSSR)
Incident investigations
Technical training
Commissioning, shake down and start up
Due diligent reviews for acquisitions
Compliance to warranty (Owners rep when dealing with RTO vendors)
Expert witness and attorney client privilege expertise
Temporary technical resources, i.e.
CAD (ACAD-2004, Mech. Desktop 2004, Rebis, and Micro Station)
Engineering and Design
MIS
PLC-Programming
Project Scheduling
Technical Writing
Training
Areas of UTI's VOC Experience and Expertise
Improving VOC capture efficiency
VOC reduction/ elimination installation designs
Design and specification for VOC emission reduction equipment and systems
Developed standard CAD details for VOC emission reduction systems
Redesigned stack and source dampers in conjunction with VOC emissions reduction equipment to improve process optimization, comply with MACT standards and reduce energy costs
Optimization of thermal oxidation systems
Specified solvent recovery coil replacements
Provided financial analysis for VOC emission reduction systems to provide the most cost effective system for given applications
Provided incident investigation for misapplied VOC emission reduction systems and equipment failures
Provided expert witness for failed VOC emission reduction systems
Development of pulp & paper plant P&ID drawings for hazardous systems involved with VOCs
Created process flow drawings & mass balance tables for VOC systems
Furnace gas train evaluation and design
Provided process hazard analysis (PHAs) for VOC processes
Provided process safety management (PSM) audits for VOC processes
List of Recent Projects
1 - Memory Tape Manufacturer PHA - 2004:
UTI has recently completed a Process Hazard Analysis (PHA) for an RTO for a memory tape manufacturer, along with other parts of the web coating and drying process. UTI's services were requested by the client after a number of fires had occurred in the system designed by others. Our Engineers identified a number of defective design aspects that we conclude contributed to unsafe conditions and to the fires. We worked with this client to resolve these issues.
2 - Expert Witness for RTO Design and Construction Failure Lawsuit - 2003-2004:
This past year UTI personnel provided expert witness testimony, on behalf of a major paper company, on the cause of an RTO failure at one of their locations. As a result, the case was settled out of court.
3 - PSM & PHAs for a Large Oven Coater Process - 2004:
We set up corporate standards for Process Safety Management (PSM) and PHAs for a number of Large Coater Clients. Their processes ranged from latex to solvent based coating and thermal oxidation.
4 - OUS Project / Brazil-Country, RTO Design and Start-Up - 2004:
UTI is assisting a Web Coating and Converting Company in the Country of Brazil to resolve a number of operational and design issues on their thermal oxidizer.
5 - RTO Engineering Design, System Configuration and Engineering Estimates – for Numerous Clients in 1999, 2000, 2001, 2002, 2003 & 2004:
UTI completed a number of RTO designs for installations of a new Regenerative Thermal Oxidizer. UTI completed design calculations, LFL determinations and evaluation of the effect on the existing waste heat recovery boiler. We have also provided preliminary engineering; such as, cost estimate for the installation, overall justification and development of procurement specifications.
6 - Conceptual Designs for RTO Systems - Develop AFE Packages for 2-qty Manufacturing Companies - 1998 -2004:
UTI recently put together a number of cost evaluations for a thermal oxidizer installation at a roofing material manufacturer and a by products manufactures here in the metro area.
7 - Solvent Recovery System Review - 2003:
UTI evaluated the specification of solvent recovery coils, system flow and material design for a magnetic tape manufacturer in California .
8 - Stack and Source System Redesign for a Number of Coater/Makers - 1998 - 2004:
UTI completed a number of VOC waste exhaust duct and damper installation project in the past 5-years. Source and stack dampers were added to a number of systems, and the ducts were resized based on changes to airflow rates and LFL levels employed in the process today.
9 - Elimination of LFL Pockets in Coaters/Makers - 2000 - 2004:
UTI is working on and has completed numerous redesign projects for coater exhaust for the elimination of high LFL pockets. UTI is presently working on some 5-coater projects today ranging from upgrading existing systems, to designing new coater exhaust systems there, and the selection and implementation of VOC equipment.
10 - Thermal Oxidizers Redesign and Reconfiguration - 2003:
UTI has completed a project to upgrade the solvent oven and thermal oxidizer ducts, dampers, and controls for a fortune 100 client
11- RTO Startup Debugging and Commissioning – 2004:
UTI was involved in the startup, debugging and commissioning of RTO equipment in Shanghai China .
12 - UTI Publication On Up Front Engineering Relative to RTOs - 2002:
UTI Vice President David Herron, P.E. published an article on RTO and up front engineering analysis for the purpose of saving energy. Please see attached PDF Article.
Locations Across the United States
Camarillo, CA
805.389.7420
Decatur, IL
217.876.7730
Kohler, WI
920.467.1440
Madison, WI
608.825.4959
Sioux Falls, SD
605.339.1250
Woodbury, MN
651.578.8100